รายละเอียดเพิ่มเติม
สเตจบ๊อก Yamaha Tio1608-D Digital Stage Box with Dante
คุณสมบัติ:
- Digital stage box for Yamaha TF series consoles
- 16 high-quality mic preamps are controllable from your console
- Connect up to 3 simultaneously for 48 inputs and 24 outputs
- Requires NY64-D Dante interface card (sold separately)
- Connects to TF series consoles via standard Cat 5e LAN cable (sold separately)
ดูสินค้ายี่ห้อ YAMAHA ทั้งหมด
ดูสินค้าสเตจบ๊อกทั้งหมด
สเปคสินค้า
Specifications
General specifications |
Tio1608-D |
Sampling frequency rate |
External |
44.1kHz or 48kHz |
Total harmonic distortion |
Less than 0.1% 4dBu@20Hz-20kHz into 600Ω Gain= 66dB / Less than 0.05% 4dBU@20Hz-20kHz into 600Ω Gain=-6dB INPUT to OUTPUT Fs=44.1kHz 48kHz *Measured with a -18dB/octave filter @80kHz |
Frequency response |
0.5 -1.5dB 20Hz-20kHz refer to the nominal output level @1kHz INPUT to OUTPUT Fs=44.1kHz or 48kHz |
Dynamic range |
108 dB INPUT to OUTPUT Gain=-6dB / 112 dB DA Converter |
Hum & noise level |
Equivalent input noise |
-128dBu Gain= 66dB *Measured with A-weighting filter |
Residual output noise |
-88dBu ST master off *Measured with A-weighting filter |
Crosstalk |
-100dB adjacent INPUT/OUTPUT channels Input Gain = -6dB *Measured with a -30dB/octave filter @22kHz |
Heat dissipation |
100-240V 50/60Hz 43.5kcal/h |
Power requirements |
100-240V 50/60Hz |
Power consumption |
50W |
Dimensions |
W |
480mm (18-7/8″) |
H |
88mm (3-4/8″) |
D |
364mm (14-3/8″) |
Net weight |
5.7kg (12.6lbs) |
Accessories |
Owner’s Manual Power Cord(2.5m) Rubber stoppers(4) |
Others |
Temperature Range: Operating temperature range: 0 – 40℃ Storage temperature range: -20 – 60℃ |
Analog Input Characteristics
Input Terminals |
GAIN |
Actual Load
Impedance |
For Use With
Nominal |
Input Level |
Connector |
Balanced /
Unbalanced |
Sensitivity*1 |
Nominal |
Max. before clip |
INPUT1-16 |
66dB |
7.5kΩ |
50-600Ω Mics &
600Ω Lines |
-82dBu (61.6μV) |
-62dBu (0.616mV) |
-42dBu (6.16mV) |
Combo Jack (XLR-3-31 type *2
or TRS phone *3) |
Balanced |
-6dB |
-10dBu (245mV) |
10dBu (2.45V) |
30dBu (24.5V) |
In these specifications 0dBu = 0.775Vrms.
48V DC (phantom power) can be supplied to INPUT XLR type connectors via each individual software controlled switch.
*1. Sensitivity is the lowest level that will produce an output of 4dBu (1.23V) or the nominal output level when the unit is set to maximum gain.
*2. 1: GND 2: HOT 3: COLD
*3. Tip: HOT Ring: COLD Sleeve: GND
Analog Output Characteristics
Output Terminals |
Actual Source
Impedance |
For Use With
Nominal |
Output Level |
Connector |
Balanced /
Unbalanced |
Nominal |
Max. before clip |
OUTPUT 1-8 |
75Ω |
600Ω Lines |
4dBu (1.23 V) |
24dBu (12.3V) |
XLR-3-32 type*1 |
Balanced |
In these specifications 0dBu = 0.775Vrms.
*1.1: GND2: HOT 3: COLD
Digital Input & Output Characteristics
Terminal |
Format |
Data length |
Level |
Audio |
Connector |
Primary/Secondary |
Dante |
24bit or 32bit |
1000Base-T |
16ch ( Tio1608-D to other devises)
8ch (Other devises to Tio1608-D) |
etherCON Cat5e |